Gas, Smoke & Heat Alarms GAS SAFE REGISTER TM

NATURAL GAS & LPG ALARMS WITH RELAY OUTPUTS

To operate gas valves, link to systems, sound remote alarms, etc
These gas alarms have a power output and push button reset for the operation and control of a gas solenoid valve (click here for these).
They will also operate an alarm, warden call, or boiler shut-down. There is a choice of integral or remote sensor. Fitted with short wiring tails and supplied with patresse box for installation purposes. Input terminals for remote gas cut-off or alarm purposes.
Available for Natural Gas or LPG.

For Natural Gas
Part No.Description Unit PriceQty

For LPG
Part No.Description Unit PriceQty



OMNITRON PLUG-IN ALARMS

Natural Gas and LPG Alarm

Plug-in audio and visual alarm to detect Natural Gas and LPG leaks.
Power supply : AC 220 V/AC 110 V.
Power frequency : 50/60Hz.
Consumption : ≤ 2 W.
Alarm level : 3% LEL - 20% LEL.
Min/max working temp. : -10°C to 40°C.
Audio alarm : 85 dB.
Reference standard : EN 50194 : 2000.
CE approved.
Part No.Description Unit PriceQty

3-in-1 Combined Alarm

Audio and visual alarm to detect smoke, Natural Gas, LPG, and carbon monoxide.
Power supply :AC 220 V/AC DC adaptor with 9 V battery back-up.
Consumption : ≤ 2.5 W.
Min/max working temp. : 4°C to 38°C.
Audio alarm : 85 dB.
Gas Sensitivity : ≤ 10%LEL
CO Sensitivity : 100 ± 50ppm
Smoke Sensitivity : Conforms to EN14604: 2001.
Gas conforms to EN 50194.
CO conforms to EN 50291: 2001.
Part No.Description Unit PriceQty



AMOS 360 CARBON DIOXIDE ALARM

The AMOS 360 CO2 detector protects by detecting the presence of increasing CO2 levels long before it reaches unsafe levels, by sounding an alarm, triggering remote alarms or switching on ventilation systems. Mainly used in the catering, pub, fermentation, chemical and plant growing industries. Complete with wall fixing back bracket.
SPECIFICATION :  
Applicable legislation : Confined Spaces Regulations 1997
Alarm trigger level : 0.5% concentration of CO2
Alarm : red warning light, sound level 85 dB at 3 m
Relay : 1 changeover relay with Volt free contacts for remote signalling, 10 A at 230 V AC or 30 V DC
Reset operation : only permitted when
gas has cleared
Alarm reset : automatic or push button.
Power : 240 V AC
Size : 110 mm x 110 mm x 57 mm
Weight : 420 g/ 15 oz
Part No.Description Unit PriceQty



KANE - ROOM CARBON DIOXIDE / TEMPERATURE MONITOR

This portable, handheld CO2 monitor measures the carbon dioxide (CO2) levels, up to 3,000 parts per million (ppm) and measures the ambient temperature over the range 0 to 50°C, using NDIR (non-dispersive infra-red sensor) technology to provide long term stability. The unit features a data logger, maximum/minimum mode, alarm mode, ALTI (compensation for changes in atmospheric pressure) mode and RCFS (recover factory setting) mode. Logs up to 48 readings at 30 minute intervals. Calculates and displays ventilation rates. Comes complete with 4 AA batteries, mains adapter and fitted with a tilt stand. DIMENSIONS : 166 mm wide x 83 mm high x 26 mm deep.
Part No.Description Unit PriceQty



XENON BEACON

Warning light which may be wired into suitable gas alarm systems to give a visual warning. One second pulses. White polycarbonate body. 230 V 3 watt.
Part No.Description Unit PriceQty



SMOKE ALARMS

DICON Smoke Alarms, Kitemarked

Battery powered alarms featuring loud piezo electric alarm, operating indicator and test button. There is a low battery warning and a battery out indicator. The battery is included. All kitemarked, to BS 5446-1:2000.

SA 900 Long Life
Approximately 10 years operation from the long life Lithium Powercell which is supplied with this alarm.
Part No.Description Unit PriceQty

Micro 300 and 300AP
General purpose alarms powered by a 9 volt battery (supplied). 300 AP has an alarm silencer button which silences alarm for 10 minutes in non-emergencies.
Part No.Description Unit PriceQty

1 Year

The SI-601 ionisation smoke alarm is battery operated and more effective at detecting fast flaming fires that burn fiercely such as chip pan fires. The SO-601 optical smoke alarm (toast proof) is battery operated and more effective at detecting slow burning fires such as foam filled furniture or over heated wiring. Less prone to nuisance alarms from cooking fumes. Press test and silence button. Low battery warning signal. Battery supplied.

SPECIFICATIONS :
Approval : BS EN 14604 : 2005. Suitable for leisure and accommodation vehicles.
Alarm : 85 dB at 3 m.
Battery : 9 V PP3 (1 year life in normal operating conditions).
Weight : 169 g (including battery).
Dimensions : dia. 131 mm x depth 34 mm.
Part No.Description Unit PriceQty

10 Year

The 10 year models are the same specification as above, apart from the batteries which are non-removable lithium power packs, with a 10 year life in normal operating conditions.

Alarm : 85 db
Weight : 195 g.
Part No.Description Unit PriceQty



KIDDE SMOKE & CO VOICE ALARM

2-IN-1 combination smoke and carbon monoxide voice alarm. Voice alarm announces loudly "FIRE! FIRE!" or "WARNING! CARBON MONOXIDE!". Easy installation, complete with low battery indicator and test/reset button. Supplied with 3 AA batteries.
Part No.Description Unit PriceQty



KITCHEN GUARD HEAT ALARM

The DICON H380i “Kitchen Guard” is a 9 volt battery operated heat alarm, designed for use in the kitchen. Detects heat not smoke. The H380i can be linked to suitable Dicon battery operated smoke alarms thereby providing maximum protection against the dangers of fire in the home. Thermistor type sensor, temperature range 54 °C to 70°C. Alarm pause facility. Test button checks sensitivity, circuits and horn. Loud 85 dB piezo electronic alarm. LED operating indicators. Designed to BS 5446-2 : 2003. Battery included.
Part No.Description Unit PriceQty