LPG Changeover Kits GAS SAFE REGISTER TM

Whilst the maximum capacity of each of the regulators is as stated below, the gas engineer/operative must ensure that the offtake of the cylinders used is adequate for the application/installation.



CHANGEOVER KITS (PROPANE)

Two Pack Automatic Changeover Kit with OPSO (Over Pressure Shut-off) (Fuji) (BS 3016)

Capacity:
Maximum inlet pressure:
Outlet pressure:
Inlet :
Outlet :

4.5 kg/hour (211 500 Btu)
20 bar (294 p.s.i.)
37 mbar (14.8" wg)
POL
1/2" BSP female.

Kit comprises one automatic changeover regulator to BS 3016, two 20" pigtails with high pressure black hose to BS 3212 : Type 2 and POL connectors incorporating excess flow and non-return valves, wall mounting bracket, and one 1/2" M x F shut-off valve.
Part No.Description Unit PriceQty

Two Pack Automatic Changeover Kit with OPSO (Over Pressure Shut-off) (RF 6030) (EN 13786)

Capacity:
Maximum inlet pressure:
Outlet pressure:
Inlet :
Outlet :

4.5 kg/hour (211 500 Btu)
20 bar (294 p.s.i.)
37 mbar (14.8" wg)
POL
1/2" BSP female.

Kit comprises one automatic changeover regulator to EN 13786 : 2004, two 20" pigtails with high pressure black hose to BS 3212 : Type 2, POL connectors incorporating excess flow and non-return valves, one 1⁄2" M x F shut-off valve, one test point adaptor, wall mounting bracket and emergency instruction plaque.
Part No.Description Unit PriceQty

Four Pack Automatic Changeover Kit with OPSO (Over Pressure Shut-off) (Fuji) (BS 3016)

Capacity :
Maximum inlet pressure :
Outlet pressure :
Inlet :
Outlet :

4.3 kg/hour (201 785 Btu)
20 bar (294 p.s.i.)
37 mbar (14.8" wg)
POL
1⁄2" BSP female.

Kit comprises one automatic changeover regulator to BS 3016, two tee pieces, two 20" and two 35" pigtails with high pressure black hose to BS 3212 : Type 2 and POL connectors incorporating excess flow and non-return valves, wall mounting bracket, and one 1⁄2" M x F shut-off valve.
Part No.Description Unit PriceQty

Four Pack Automatic Changeover Kit with OPSO (Over Pressure Shut-off) (RF 6030) (EN 13786)

Capacity:
Maximum inlet pressure:
Outlet pressure:
Inlet :
Outlet :

4.5 kg/hour (211 500 Btu)
20 bar (294 p.s.i.)
37 mbar (14.8" wg)
POL
1/2" BSP female.

Kit comprises one automatic changeover regulator to EN 13786:2004, two tee pieces, two 20" and two 35" pigtails with high pressure black hose to BS 3212 : Type 2, POL connectors incorporating excess flow and non-return valves, one 1⁄2" M x F shut-off valve, one test point adaptor, wall mounting bracket and emergency instruction plaque.
Part No.Description Unit PriceQty

Two Pack Automatic Changeover Kit with OPSO (Over Pressure Shut-off) (EN 13786)

Capacity :
Maximum inlet pressure :
Outlet pressure :
Inlet :
Outlet :
4 kg/hour (189 000 btu)
20 bar (294 p.s.i.)
37 mbar (14.8" wg)
POL
1⁄2" BSP female
Kit comprises one automatic changeover regulator to EN13786:2004, two 20" pigtails with high pressure black hose to BS 3212 : Type 2, POL connectors incorporating excess flow and non-return valves and one 1⁄2" M x F shut-off valve, wall mounting bracket, (including test point).
Part No.Description Unit PriceQty

Two Pack Automatic Changeover Kit (EN 13786)

Capacity :
Maximum inlet pressure :
Outlet pressure :
Inlet :
Outlet :
4 kg/hour (189 000 btu)
20 bar (294 p.s.i.)
37 mbar (14.8")
POL
1⁄2" BSP female
Kit comprises one automatic changeover regulator to EN13786:2004, two 20" pigtails with high pressure black hose to BS 3212 : Type 2, POL connectors incorporating excess flow and non-return valves, wall mounting bracket, and one 1⁄2" M x F shut-off valve, (including test point).
Part No.Description Unit PriceQty

Two Pack Automatic Changeover Kit (RF6000) (BS 3016)

Capacity :
Maximum inlet pressure :
Outlet pressure :
Inlet :
Outlet :
4.3 kg/hour (201 785 Btu).
20 bar (294 p.s.i.).
37 mbar (14.8" wg).
POL
3/8" BSP female.
Kit comprises one automatic changeover regulator to BS 3016, two 20" pigtails with high pressure black hose to BS 3212 : Type 2 and POL connectors incorporating excess flow and non-return valves, wall mounting bracket, one 1/2" x 3/8" nipple, and one 1/2" F x F shut-off valve.
Part No.Description Unit PriceQty

Two Pack Automatic Changeover Kit (BS EN 13786)

Capacity :
Maximum inlet pressure :
Outlet pressure :
Inlet :
Outlet :
5 kg/hour (238,000 Btu)
16 bar (235 p.s.i.)
37 mbar (14.8" wg)
POL
1⁄2" BSP female
Kit comprises one automatic changeover regulator to BS EN 13786: 2004, two 20" pigtails with high pressure black hose to BS 3212 : Type 2 and POL connectors incorporating excess flow and non-return valves, built in wall mounting bracket and 1⁄2" F x F shut-off valve.
Part No.Description Unit PriceQty

Automatic Changeover Regulator (BS EN 13786)

Capacity :
Maximum inlet pressure :
Outlet pressure :
Inlet and outlet threads :
5 kg/hour (238,000 Btu).
16 bar (235 p.s.i.).
37 mbar (14.8" wg).
M20.
Compact automatic changeover propane regulator without OPSO, complies with BS EN 13786: 2004.
Part No.Description Unit PriceQty

Two Pack Automatic Changeover Kit with OPSO (Over Pressure Shut Off) (BS EN 13786)

Capacity :
Maximum inlet pressure :
Outlet pressure :
Inlet :
Outlet :
4.5 kg/hour (214 500 Btu).
20 bar (294 p.s.i.).
37 mbar (14.8" wg).
POL
1/2" BSP female.
Kit comprises one automatic changeover regulator to BS EN 13786, two 20" pigtails with high pressure black hose to BS 3212 : Type 2 and POL connectors incorporating excess flow and non-return valves, wall mounting bracket, and one 1/2" F x F shut-off valve.
Part No.Description Unit PriceQty

Four Pack Automatic Changeover Kit with OPSO (Over Pressure Shut Off) (BS EN 13786)

Capacity :
Maximum inlet pressure :
Outlet pressure :
Inlet :
Outlet :
4.5 kg/hour (214 500 Btu).
20 bar (294 p.s.i.).
37 mbar (14.8" wg).
POL
1/2" BSP female.
Kit comprises one automatic changeover regulator to BS EN 13786, two tee pieces, two 33" and two 20" pigtails with high pressure black hose to BS 3212 : Type 2 and POL connectors incorporating excess flow and non-return valves, wall mounting bracket, and one 1⁄2" F x F shut-off valve.
Part No.Description Unit PriceQty

Spare Mounting Bracket for Changeover Kits

For use with P/Ns 7436,6900 and 8820
Part No.Description Unit PriceQty

Two to Four Pack Conversion Kit

Converts two pack system to four pack. Pigtails utilize high pressure black hose to BS 3212 : Type 2 and POL connectors incorporating excess flow and non-return valves.
Part No.Description Unit PriceQty

Manual Changeover Valve

As used in the manual changeover kits above.
Part No.Description Unit PriceQty

Manual Changeover Kits

Capacity :
Maximum inlet pressure :
Outlet pressure :
Inlet :
Outlet :

4 kg/hour (189 000 Btu)
20 bar (294 p.s.i.).
37 mbar (14.8" wg).
POL
3/8" BSP female.
P/N 8820. Kit comprises one manual changeover valve, one regulator, and two 20" pigtails with high pressure black hose to BS 3212 : Type 2 and POL connectors incorporating excess flow and non-return valves.
P/N 12679. Kit as P/N 8820 above plus a mounting bracket (as illustrated) and a 1/2" Fx F shut-off valve.
Part No.Description Unit PriceQty



HIGH OUTLET PRESSURE AUTOMATIC CHANGEOVER KITS, FOR PROPANE
1 BAR OR 1.5 BAR OUTLET PRESSURE


Changeover kits which deliver a high pressure (1 or 1.5 bar) and not the 37 mbar used at the appliance. A SECOND STAGE REGULATOR IS REQUIRED IN ADDITION TO THESE KITS TO BRING THE PRESSURE DOWN TO 37 MBAR.
Kits comprise one automatic changeover regulator, two 20" pigtails with high pressure black hose to BS 3212 : Type 2, POL connectors incorporating excess flow and non-return valves, and a 1/2 " F x F shut-off valve. The four cylinder kit also includes two 33" pigtails of similar specification.

Two Cylinder Kit, 1 Bar Outlet Pressure

Capacity :
Inlet pressure :
Operating pressure :
Inlet :
Outlet :
8 kg (375 000 Btu) per hour
2- 20 bar (30-294 p.s.i.).
1 bar (14.7 p.s.i ).
POL
1/2 " BSP F shut-off valve
Kit comprises one automatic changeover regulator, two 20" pigtails with high pressure black hose to BS 3212 : Type 2, POL connectors incorporating excess flow and non-return valves, and one 1/2 " F x F shut-off valve. The four cylinder kit also includes two 33" pigtails of similar specification.
Part No.Description Unit PriceQty

Four Cylinder Kit

Capacity :
Inlet pressure :
Operating pressure :
Inlet :
Outlet :
8 kg (375 000 Btu) per hour
2- 20 bar (30-294 p.s.i.).
1 bar (14.7 p.s.i ).
POL
1/2 " BSP F shut-off valve
Kit comprises one automatic changeover regulator, two 20" pigtails with high pressure black hose to BS 3212 : Type 2, POL connectors incorporating excess flow and non-return valves, and one 1/2 " F x F shut-off valve. The four cylinder kit also includes two 33" pigtails of similar specification.
Part No.Description Unit PriceQty

Two Cylinder Kit, 1.5 Bar Outlet Pressure

Capacity :
Maximum inlet pressure :
Outlet pressure :
Inlet :
Outlet :
12.5 kg/hour (594,000)
16 bar (235 p.s.i.)
1.5 bar (22 p.s.i.)
POL
1⁄2" BSP F shut-off valve
Kit comprises one automatic changeover regulator to BS EN 13786: 2004, two 20" pigtails with high pressure black hose to BS 3212: Type 2, POL connectors incorporating excess flow and non-return valves, built-in wall mounting bracket and 1⁄2" F x F shut-off valve.
Part No.Description Unit PriceQty