Refrigeration - Insulation, Flexible Connectors, Clips

CLASS O ARMAFLEX

Armaflex is a flexible, closed cell, elastometric, nitrile rubber insulation. It is a highly efficient method of insulating hot and cold water services, chilled water lines, heating systems, air conditioning ductwork and refrigeration pipework for frost protection, energy conservation and condensation control. Armaflex is dust, fibre and CFC free with an ODP of zero which means an environmentally friendly product. P/Ns 14927 to 14946 supplied in 2m lengths. P/Ns 14947 to 14960 supplied in various coiled lengths.



SPECIFICATION :
Temperature range: minimum line temperature - 40 °C
maximum line temperature +105 °C
Thermal conductivity: to BS 874 part 2 1986
Water vapour permeability: to BS 4370 part 2 1973
Fire propogation: to BS 476 part 6 1989
Fire performance: to BS 478 part 7 1987
Noise reduction: DIN 4109 : to 30 dB (A)

For metric copper tube use.
15mm = 5⁄8" 35mm = 1.3⁄8"
22mm = 7⁄8" 42mm = 1.5⁄8"
28mm = 1.1⁄8" 54mm = 2.1⁄8"

Note first size below is the bore, second size is the wall thickness.

Part No.Description Unit PriceQty

Self-adhesive Tape

Self-adhesive tape for securing the above insulation.
Part No.Description Unit PriceQty



CLASS O ARMAFLEX SELFSEAL

Armaflex selfseal is a closed cell, elastomeric, nitrile rubber insulation, with in-built anti-microbial protection, fully slit along each length with double sided adhesive tape pre-applied to each open slit. Built in vapour barrier prevents condensation. It is a highly efficient method of insulating hot and cold water services, chilled water lines, heating systems; outdoor applications require special paint finish for frost protection.

SPECIFICATION :
Temperature range: minimum surface -50°C
maximum surface +105°C
Thermal conductivity: to EN ISO 8497: 1997
Water vapour permeability: to BS EN ISO 9346: 1996
Fire propogation: to BS 476 Part 6: 1989
Surface spread of flames: to BS 476 Part 7: 1997
Noise reduction: to ISO 354: 2003 up to 0.8
   
For metric copper tube use.  
  15mm = 5⁄8" 35mm = 1.3⁄8"
  22mm = 7⁄8" 42mm = 1.5⁄8"
  28mm = 1.1⁄8" 54mm = 2.1⁄8"

Note first size below is the bore, second size is the wall thickness.

Part No.Description Unit PriceQty



FAN COIL ASSEMBLIES - PAMET

PAMET braided fan coil flexible connectors can be used for the final connection to fan coil units. They are manufactured to reduce possible vibration and offer a high degree of flexibility allowing misalignment of pipework.

SPECIFICATION :
Hose : PAMET stainless steel 321 annular corrugated and a single stainless steel AISI 304 external wire braid.
End connections : Manufactured in carbon steel.
P/N 14863 to 14871 : One end terminated with a BSP swivel female complete with a flat seat. Other end with a BSPT hexagon fixed male connection.
P/N 14872 to 14880 : Both ends terminated with BSPT hexagon fixed male connections.
Safe working pressure : fitting size : 1/2" 70 bar, 3/4" 50 bar, 1" 40 bar

Part No.Description Unit PriceQty

Part No.Description Unit PriceQty



FAN COIL HOSE ASSEMBLIES - HYDRAQUIP

HYDRAQUIP fan coil hoses /anti-vibration hoses suitable for all plumbing and heating applications. The lining is non-toxic, suitable for drinking water in commercial and domestic applications. The temperature range makes them suitable for heating, air conditioning, pumps, boilers, autoclaves and fan coil units.

SPECIFICATION :
304 grade stainless steel braid with high quality EPDM liner.
AISI 303 stainless steel crimping ferrules.
Brass nickel plated heavy type end fittings.
Working pressure : 1/2 " 20 bar
3/4 " 16 bar
Temperature range : -20 °C to +110 °C

Part No.Description Unit PriceQty

Part No.Description Unit PriceQty

Part No.Description Unit PriceQty



PIPEWORK FIXING CLIPS

Channel Clips (RPC ®)

RPC ® channel clips, used in refrigeration and air conditioning to secure imperial tube. Fit standard 41 mm wide channel.
To establish the correct clip size add any insulation thickness to the pipe outside diameter before selecting inside diameter for the clip.
Part No.Description Unit PriceQty

InsulClip

InsulClip has been developed to allow installation of air conditioning and refrigeration and plumbing pipework together with any required insulation material of either 9 mm or 13 mm thickness, and also electrical conduit of 20 mm and 25 mm. It allows an unbroken vapour barrier seal which eliminates sweating on metal fittings where VRV systems are installed. Fit standard 41 mm wide channel.

To establish the correct clip size add any insulation thickness to the pipe outside diameter before selecting inside diameter for the clip.
Part No.Description Unit PriceQty

Studding Clips

RPC ® studding clips are quick and simple to use, fitting conventional 8 mm and 10 mm threaded rod. The 10 mm clips also fit a 3/8 " US standard thread. NOTE that studding is not supplied with clips.

To establish the correct clip size add any insulation thickness to the pipe outside diameter before selecting inside diameter for the clip.


8mm Thread Size
Part No.Description Unit PriceQty

10mm Thread Size
Part No.Description Unit PriceQty

Pipe Holders

'SQUEEZY-FIT' supports a pair of flow and return insulated copper air conditioning pipes on either M8 or M10 threaded rod.
Part No.DescriptionLiquid Pipe dia.Gas Pipe dia.Threaded Rod dia. Unit PriceQty