Part Number: 8959
Gas Control Valve Tap with Flame Supervision 0 to 120°C
CE certified to the relevant requirements of EN 125, EN 126 and EN 1106 (Certificate No. E6055).
This valve has flame failure protection and will give a variable gas flow between low and full rates.
Flow rate for Natural Gas at 20 mbar. : FULL ON 1.5 m³/h.; LOW (adjustable) 0.02 to 0.55 m³/h.
Operating sequence : Off, Pilot, Pilot + minimum flow, Pilot + maximum flow.
Connections : inlet and outlet are for 8 mm o.d tube; pilot is for 4 mm o.d. tube; thermocouple is M8.
Fascia nut is M15 (P/N 9686).
Supplied with control knob (P/N 17375), nuts and olives.
This valve has flame failure protection and will give a variable gas flow between low and full rates.
Flow rate for Natural Gas at 20 mbar. : FULL ON 1.5 m³/h.; LOW (adjustable) 0.02 to 0.55 m³/h.
Operating sequence : Off, Pilot, Pilot + minimum flow, Pilot + maximum flow.
Connections : inlet and outlet are for 8 mm o.d tube; pilot is for 4 mm o.d. tube; thermocouple is M8.
Fascia nut is M15 (P/N 9686).
Supplied with control knob (P/N 17375), nuts and olives.
Product Specification
Standards | EN 125, EN 126 and EN 1106 |
Connection | 8 mm inlet & outlet, 4 mm pilot |
Flow Rate | FULL ON 1.5 m³/h NG at 20 mbar |
Max. Operating Temperature | 0 to 120°C |
Size | 8 mm |
Suitable Application | Decorative fuel effect fires; but is also suitable for a wide range of domestic and commercial heating and cooking appliances. For use with Natural Gas (NG) and LPG. |
Type | Gas Tap |