Part Number: 8959

Gas Control Valve Tap with Flame Supervision 0 to 120°C

CE certified to the relevant requirements of EN 125, EN 126 and EN 1106 (Certificate No. E6055).
This valve has flame failure protection and will give a variable gas flow between low and full rates.
Flow rate for Natural Gas at 20 mbar. : FULL ON 1.5 m³/h.; LOW (adjustable) 0.02 to 0.55 m³/h.
Operating sequence : Off, Pilot, Pilot + minimum flow, Pilot + maximum flow.
Connections : inlet and outlet are for 8 mm o.d tube; pilot is for 4 mm o.d. tube; thermocouple is M8.
Fascia nut is M15 (P/N 9686).
Supplied with control knob (P/N 17375), nuts and olives.

Product Specification

Standards EN 125, EN 126 And EN 1106
Connection 8 Mm Inlet & Outlet, 4 Mm Pilot
Flow Rate FULL ON 1.5 M³/h NG At 20 Mbar
Max. Operating Temperature 0 To 120°C
Size 8 Mm
Suitable Application Decorative Fuel Effect Fires; But Is Also Suitable For A Wide Range Of Domestic And Commercial Heating And Cooking Appliances.
For Use With Natural Gas (NG) And LPG.
Type Gas Tap