Anyone who’s re-run a gas supply in copper knows the drill: bends, joints and hot works the whole way. Flexible stainless steel gas pipe, or CSST (corrugated stainless steel tubing), does away with most of that. It comes off the coil in one continuous length and bends by hand, so the run from the meter to a boiler, hob or fire needs very few joints.
We stock three of the main systems: TracPipe and TracPipeCC, Gastite and Gas Flex Systems (GFS), in sizes from DN12 to DN50. Each comes with its own fittings, so you’ll find the pipe coils alongside installer and replacement kits, plus the matching tees, couplings, BSP adaptors, copper transition fittings and spare seals.
Read More
Every product below belongs to one system, so choose the brand first and then the size.
The pipe is a thin-walled corrugated stainless-steel tube inside a polyethylene cover. TracPipe runs from 12mm to 50mm in coils of 30m up to 90m, with the TracPipe Flexible Steel Gas Pipe - 22mm x 30m at the domestic end of the range. Gastite coils cover DN15 to DN50 in 30m, 45m and 75m lengths, the Gastite Steel Flexible Gas Pipe Coil - DN25 x 30m among them. GFS pipe comes in DN15 to DN32 with 15m, 30m and 60m lengths, including the GFS Flexible Steel Gas Pipe - DN20 x 30m. For a single short run, the TracPipe and TracPipeCC installer kits provide a 5m, 10m or 15m coil with silicone tape, such as the TracPipe Gas Pipe Installer Kit - DN15 x 10m Coil.
Swapping out an undersized or damaged copper supply is the classic job for these kits, because the coil arrives with an end fitting for each end. The TracPipe Pipe Replacement Kit 22mm x 10m Coil - 3/4" includes two AutoFlare male BSP taper fittings and 2m of self-amalgamating silicone tape. With Gastite, the tube coils carry two XR2 straight male BSP fittings, as on the Gastite Tube Coil DN25 x 10m - 1" BSP TM. The GFS Contractors Kit DN20 x 10m - 3/4" BSP TM pairs the pipe with two connector fittings and a metre of yellow self-amalgamating tape.
Adding a second appliance to an existing run calls for a tee. Product names list the two run ends first and the branch last, so a DN25 x DN20 x DN15 tee steps down on one end and again on the branch. Equal tees, such as the AutoFlare Equal Tee - 22mm, suit a branch the same size as the main run. Reduced versions, for instance the GFS One End & Branch Reduced Tee DN25 x DN20 x DN15, avoid the need for a separate reducer. On Gastite pipe, the Gastite XR2 Mechanical Tee - DN15 x DN15 x DN15 is one of three equal mechanical tees.
When a run is longer than the coil, or the manufacturer allows a damaged section to be cut out and rejoined, a coupling connects two lengths of the same pipe. Straight couplings join equal sizes, from the AutoFlare Coupling - DN15 upwards, while reducing couplings like the GFS Reducing Coupling - DN25 x DN20, change size in line. Mechanical couplings, including the Gastite XR2 Mechanical Coupling - DN20, perform the same job on Gastite pipe.
Most flexible runs end on a thread, at an appliance isolation valve, a meter outlet or a rigid pipe fitting. A male BSP taper (TM) end screws into a female thread, and a female (F) end takes a male one, so check what you're connecting to before you order. The AutoFlare Gas Straight Fitting 22mm x 3/4" BSP TM and the GFS Straight Male Connection - DN25 x 1" BSP TM are typical male ends. For a female connection, there's the AutoFlare Gas Pipe Straight Fitting DN28 x 3/4" BSP F or the Gastite XR2 Female Coupler Adaptor - DN15 x 1/2" BSP F. Apply jointing compound or tape on the male pipe thread only, never to the sealing faces inside the fitting.
Many installations use both materials, with flexible pipe through the awkward part of the route and copper where the pipe is exposed or runs straight. These fittings have a flexible-pipe connection on one side and a compression joint for copper tube on the other. In a name like DN22 x 15mm, the DN figure is the flexible pipe and the millimetre figure is the copper. The AutoFlare Straight Compression - DN22 x 22mm is a straight TracPipe-to-copper joint, and the TracPipe to Copper Comp. Elbow DN28 x 28mm turns 90° at the same time. GFS compression couplings start at the GFS Compression Coupling - DN15 x 15mm, and Gastite XR2 versions include the Gastite XR2 Copper Compression Fitting - DN20 x 15mm.
It's worth keeping a few spares in the van. On a TracPipe joint, two half-split rings sit in the first corrugation behind the cut and are held by the back nut. They come in packs, such as the TracPipe Fitting Half Split Ring - 15mm Pack of 10. If the seal on a GFS fitting is damaged, or you're reusing the fitting, swap in a new gasket and compression washer, for example the GFS Silicone Gasket - DN25. Silicone tape, up to the Silicone Tape - 50mm x 11m, wraps any stainless steel left exposed at a TracPipe fitting after the tightness test.
The three systems do the same job, but their fittings aren't interchangeable, even at the same DN size. Match each fitting to the brand of pipe that's actually installed. Within Gastite, check the generation as well, because the XR2 DN20 fittings aren't compatible with the earlier Gastite DN20 pipe and fittings.
|
|
TracPipe & TracPipeCC |
Gastite |
GFS (Gas Flex Systems) |
|
Pipe sizes at BES |
12mm to 50mm (DN12 to DN50) |
DN15 to DN50 |
DN15 to DN32 |
|
How the fitting seals |
AutoFlare brass fitting forms a flare on the pipe end as it's tightened, giving a metal-to-metal seal |
XR2 brass fitting with a tool-less flare, metal-to-metal seal and Jacket-Lock to cover the steel behind the nut |
Nickel-coated DZR brass fitting with a silicone rubber seal, brass compression washer and gripping collet |
|
Reusing fittings |
Spare split rings available; follow the TracPipe instructions |
XR2 components are listed as fully reusable |
Can be reused with a new silicone gasket and compression washer |
|
Standards on BES listings |
BS EN 15266 (Kitemark KM 549666) and BS 7838; TracPipeCC is assessed separately by BSRIA |
BS EN 15266 |
BS EN 15266 and BS 7838 |
TracPipeCC (Complete Containment) is standard TracPipe with a second outer cover. Ridges inside that cover give any escaping gas a path to ventilated areas at the ends of the pipe, which is why it's chosen for routes through unventilated voids and specified hazardous areas. It takes the same AutoFlare fittings. A red pulling cord built into the cover lets you strip back the outer layer before the fitting goes on. The TracPipeCC Flexible Steel Gas Pipe - 28mm x 30m and the TracPipeCC Gas Pipe Installer Kit - DN22 x 10m Coil are two of the sizes we carry.
All gas work on these systems must be carried out by a Gas Safe registered engineer, following the manufacturer’s instructions and the relevant standard: BS 6891 or BS 5482-1 in domestic premises, IGEM/UP/2 elsewhere.
Size the pipe by calculation rather than matching the copper it replaces. The calculation takes in the gas rate of every appliance, the length of the run and the pressure drop allowed, which TracPipe’s design guide puts at 1 mbar from meter to appliance on natural gas. Bores also vary by brand, so use the sizing tables for the system you’re installing. 22mm TracPipe has a 20.8mm bore, for example, while Gastite DN20 is 20.1mm inside. There’s no single pressure rating for the whole page either. Check the product page, and remember the installation is only as good as its lowest-rated component.
TracPipe and TracPipeCC can be buried underground or laid in non-structural screed without extra corrosion protection. They can’t go in structural floors, power-floated slabs or floors with electric underfloor heating, and AutoFlare fittings must always stay accessible in a ventilated space, never buried. For Gastite and GFS, check the manufacturer’s guidance before burying any part of the run.
When making a joint, stick to fittings from the same system and generation. Cut the pipe square with a tube cutter that reaches the bottom of the corrugation, then strip back only as much cover as the instructions say (about 25mm on TracPipe). Make up the fitting as the manufacturer describes, keeping jointing compound off the internal sealing faces. Fit a temporary continuity bond before breaking into existing metal pipework, then tightness test and wrap any exposed stainless steel with silicone tape.
Flexible gas pipe is for fixed installation pipework only. It shouldn’t be bent repeatedly once installed or used to connect a cooker that moves; that’s a job for an approved gas cooker hose.
Finishing the job takes more than the pipe. Our gas pressure testing equipment and gas leak detection ranges cover the tightness test and the leak check, and our gas valves include the appliance isolation valves a flexible run usually ends on. If you'd rather run part of the supply in a different material, browse the full gas pipes and fittings range, which includes MDPE and through-the-wall options.
Not sure which brand of pipe is already in a property, or which fitting suits it? Send us the details through our technical request form. We've supplied gas engineers for more than 50 years, and you can order online for delivery or use Click & Collect, with 30-day returns subject to our terms.
What is flexible gas pipe?
Flexible gas pipe, or CSST, is corrugated stainless steel tubing with a protective plastic cover, used for fixed gas installation pipework. It's supplied on a coil, bends by hand, and is joined with brand-specific mechanical fittings, so a run usually needs fewer joints than copper and no soldering. The systems we stock are TracPipe, TracPipeCC, Gastite and GFS.
Is flexible gas pipe allowed in the UK?
Yes. The pipe on this page is listed to BS EN 15266, and TracPipe and GFS are also listed to BS 7838. It must be installed by a Gas Safe registered engineer in accordance with the manufacturer's instructions and the relevant standard, which is usually BS 6891 or BS 5482-1 in homes and IGEM/UP/2 in larger or commercial premises.
Can I mix TracPipe, Gastite and GFS fittings?
No. Each brand's fittings are made for its own pipe, and a fitting with the same DN size from another brand isn't made to seal on it. Within Gastite, the XR2 DN20 fittings aren't compatible with earlier Gastite DN20 pipe or fittings either. If you're working on an existing installation, identify the brand from the markings on the cover first.
What size flexible gas pipe do I need?
It depends on the appliances' gas rates, the length of the run and the permitted pressure drop, so it must be calculated using the manufacturer's sizing tables. Don't assume 22mm flexible pipe matches 22mm copper, as bores vary by brand. We stock TracPipe from 12mm to 50mm, Gastite from DN15 to DN50 and GFS from DN15 to DN32.
Can flexible gas pipe be buried or laid in screed?
TracPipe and TracPipeCC are suitable for burial underground or direct installation in non-structural screed without additional corrosion protection, provided the manufacturer's instructions are followed. They must not be installed in structural floors, and the AutoFlare fittings must never be buried. For Gastite and GFS, consult the manufacturer's guidance first.
Can flexible gas pipe be used to connect a cooker?
No. CSST is installation pipework, not an appliance connector, and it shouldn't be repeatedly bent once it's in place. A freestanding cooker needs an approved flexible cooker hose with a bayonet or other suitable connection, fitted to the end of the fixed pipework.
Can flexible gas pipe fittings be reused?
Gastite lists its XR2 fitting components as fully reusable. GFS fittings can be reused with a new silicone gasket and compression washer, and we sell both as spares. For TracPipe, follow the AutoFlare instructions and use new split rings where needed. Whichever system you use, inspect the parts and perform a tightness test after remaking any joint.
Do I need special tools to install flexible gas pipe?
Not usually. A tube cutter with a wheel that reaches the bottom of the corrugation, a sharp knife for the cover, and the right spanners will cover most jobs. There's no soldering or hot work at the joints. You'll still need tightness-testing equipment, and some sizes require a specific tightening procedure, so check the system instructions.