Sealed heating systems slowly lose a little water through radiator bleeding, servicing and small leaks, and the boiler pressure gauge drops as a result. A filling loop is the temporary link between the cold mains and the heating circuit that lets you top it back up, with a double-check valve to stop heating water from getting back into the drinking water supply.
All our filling loops feature 15mm compression ends, a metal-braided flexible hose and a DZR brass double-check valve. Choose from straight and tee versions with one or two stop valves, a remote loop with its own pressure gauge, and an auto-fill loop with a pressure-reducing valve. For combi boilers, system boilers and conversions to a sealed system, there's also a complete Inta sealed-system kit.
Read More
The differences come down to how the loop connects to the pipework, how many valves it has, and whether you can read the system pressure at the loop itself.
For a simple connection between two 15mm pipes, a straight loop is the standard choice. The Straight Filling Loop with Valve - 15mm has a brass stop valve at one end and a DZR double check valve at the other. The Straight Filling Loop with Two Stop Valves - 15mm adds a stop valve built into the double check valve, so both ends can be shut off before the hose is removed. Its components are WRAS approved.
Where the loop connects partway along an existing run of pipe, a tee stop valve avoids the need to fit a separate tee. The Straight Filling Loop with Tee - 15mm pairs a brass tee stop valve with a DZR double check valve. For isolation at both ends, the Straight Filling Loop with Tee Stop Valve - 15mm uses a plated tee isolating valve and a double check valve with its own built-in stop valve.
A boiler tucked inside a kitchen cupboard or loft makes it awkward to watch the gauge while opening the valves. The WRAS-approved Remote Filling Loop with Gauge - 15mm Compression lets you fill from a more accessible point, with a 4 bar pressure gauge on its DZR stop valve so you can see the system pressure where you're working. It also includes a double check valve with a built-in stop valve.
The Auto-fill Loop with PRV - 15mm adds an adjustable pressure-reducing valve to the standard brass stop valve, braided hose and DZR double-check valve with built-in stop valve. The PRV limits the pressure entering the system, so the fill is controlled by the valve setting rather than by how quickly you close the tap. Check the setting against the boiler manufacturer's recommended system pressure before filling.
Converting an open-vented system to sealed, or fitting a heat-only boiler on a sealed circuit, requires more than a filling loop. The Inta Trade-Tec Sealed System Kit - 15mm contains a 3 bar safety relief valve with pressure gauge, a 4-way brass manifold, and a filling loop with isolating valves, one with a double check valve assembly. Inta lists it for 4°C to 99°C and up to 50% glycol. The kit doesn't include an expansion vessel, so add one sized for the system from our expansion vessels range.
|
Filling loop |
Pipe connection |
Stop valves |
Gauge |
WRAS approval stated |
|
Straight with Valve |
Straight |
One |
No |
No |
|
Straight with Two Stop Valves |
Straight |
Two |
No |
Yes |
|
Straight with Tee |
Tee |
One |
No |
No |
|
Straight with Tee Stop Valve |
Tee |
Two |
No |
No |
|
Remote with Gauge |
Straight |
Two |
4 bar |
Yes |
|
Auto-fill with PRV |
Straight |
Two, plus PRV |
No |
No |
All have 15mm compression ends, a metal-braided hose and a DZR double-check valve. Where approval isn't stated, check the individual product page or ask our team before specifying.
Start with the system cold and check the gauge on the boiler. Many boilers run at around 1 to 1.5 bar when cold, but the figure in the boiler manual is the one to follow. If the filling loop hose has been removed, connect it between the two valves, hand-tighten it, then tighten the compression nuts.
Open the heating-side valve first, then slowly open the mains-side valve and watch the gauge rise. Close both valves as soon as it reaches the target pressure, as overfilling can make the 3 bar safety valve discharge. Then disconnect the hose, catch any water left in it, and check both valves for drips.
If the pressure keeps dropping after a top-up, there’s usually a reason. Look for leaks at radiators and joints, check whether the pressure relief valve is discharging water, and check the air charge in the expansion vessel.
A filling loop is one part of a sealed system. Replacement pressure relief valves and expansion vessels cover the other two, and our single and double check valves and pressure reducing valves are available separately for building your own fill point. For bypass, radiator and venting valves, see our full central heating valves range.
We've supplied heating engineers for more than five decades, with next working day delivery available. Need help matching a loop to a specific boiler? Call us on 0800 801090.
What is a filling loop used for?
A filling loop connects the cold mains to a sealed central heating system, allowing you to fill it or top up the pressure. It consists of a flexible hose, stop valves and a double check valve that prevents heating water from flowing back into the mains. Combi and system boilers both rely on one, whether it's external or built in.
Should a filling loop be disconnected after use?
Yes, it's good practice. Water Regs UK guidance recommends removing the flexible hose when it isn't in use. If only one end is disconnected, it should be the end between the hose and the double check valve on the mains side to prevent contamination of the supply.
Why does a filling loop need a double check valve?
The Water Fittings Regulations don't allow a permanent filling connection to a heating system without approved backflow protection. Heating water in a house is fluid category 3, and a double check valve is the device that protects against it. Commercial heating systems are category 4 and require a higher level of protection.
What pressure should a boiler be?
Many sealed systems operate at around 1 to 1.5 bar when cold, rising when the heating is on. The correct figure varies between boilers, so check the manufacturer's instructions. If the gauge goes above 3 bar, the safety relief valve on a typical domestic system is likely to open.
Why does my boiler keep losing pressure?
The common causes include leaks in the pipework, radiators or valves, a pressure relief valve that's leaking, or an expansion vessel that has lost its air charge. Topping up via the filling loop restores the pressure, but if it keeps dropping, the cause needs to be traced by a heating engineer.
What's the difference between a straight and a tee filling loop?
A straight loop connects to the end of a 15mm pipe or another fitting. A tee loop has a tee stop valve that fits into an existing run of pipe, so you don't need a separate tee to create the fill point. Both have 15mm compression ends.
Do I need a filling loop for a combi boiler?
Yes, every combi needs a way to top up. Many combis have an integral filling link or key built in, while others use an external braided filling loop fitted under the boiler. Check the installation manual to confirm which applies before ordering.
What does an auto-fill loop with PRV do?
It has an adjustable pressure-reducing valve that limits the pressure going into the heating system, so you aren't relying solely on closing the valve at the right moment. Set it to the boiler manufacturer's recommended pressure before filling.