Brewer, MAD and Colt cowls make up most of our range, with something for almost every pot on the stack. We stock birdguards for gas, oil and solid-fuel flues, Rotorvent and spinner cowls for downdraught, Brewer’s Windmaster for wood and coal, and cappers and top lids for chimneys that are no longer in use.
Relining a chimney? We also stock liner-mounted cowls, pot hangers and adaptors that join a stove pipe to a flexible liner. Before ordering, check the fuel the flue serves, as this determines the mesh type, and check the internal diameter of the pot or the size of the liner.
Read More
Our cowls come in strap-fixed, push-in, sprung and liner-mounted designs, so the way the pot is built often narrows the choice before the fuel does.
A birdguard keeps nesting birds and debris out of a working flue while letting combustion products out freely. Mesh size is the key consideration. Gas models use a finer mesh to BS 5871, such as the High Top Birdguard - Gas Flue Only and the Brewer Round Birdguard - Gas/Oil, while solid fuel versions like the Brewer Round Birdguard - Solid Fuel have a larger mesh that's less likely to become clogged with soot. For square pots, Brewer's square birdguards fit 6" to 10" internal sizes. The galvanised Brewer Balloon Birdguard - 150mm simply pushes into the pot and comes in sizes from 64mm to 228mm. The Burford Sprung Birdguard springs out to grip round or square pots up to 250mm. Where a flexible liner terminates in the pot, the Colt High Top Flex Birdguard - 125mm straps to both the liner and the pot.
If smoke or fumes blow back into the room on windy days, the wind is pushing down the flue faster than the fire can draw. Colt's Rotorvent cowls use a wind-driven revolving head to keep the flue drawing, with the Colt Ultralite 2 Rotorvent Cowl - 80 to 250mm in black powder-coated aluminium and the Colt Mini Rotorvent Cowl - 80 to 160mm for smaller flues. Both are certified to BS EN 1856-1 and BS EN 16475-7. The static Brewer Ultimate Flue Outlet U.F.O. Mk II suits gas appliances to BS 5871, including decorative fuel effect fires, and is OFTEC performance-tested for oil. For lined flues, the MAD Anti-Downdraught Chimney Liner Cowl - 5" connects directly to a 5" liner without removing the pot.
MAD's spinning cowls are a simpler revolving option, made from stainless steel and aluminium and supplied with stainless-steel strap fixings. The Spinner Cowl - Strap Fixing, 180 to 250mm, suits most standard pots, and the Mini Anti-Downdraught Spinner Cowl - Strap Fixing covers flues from 80 to 180mm, including landfill ventilation pipes. Both are tested to BS EN 1856-1, rated for flue gases up to 200°C, and listed for all fuel types.
When you're not sure how the chimney will be used in future, an all-purpose cowl protects against rain, birds and downdraught in one fitting. The Colt Top Chimney Cowl - Hookbolt & Strap Fixings fits 125 to 250mm pots, and the Colt Top 2 Chimney Cowl - Strap Fixing fits 170 to 250mm. Both are aluminium with a terracotta finish and a stainless-steel birdguard. The Top 2 is made from 1.6mm aluminium. The Colt Econotop® Chimney Cowl, Strap Fix is a lower-cost alternative for 150 to 250mm pots. For coal and wood, Colt recommends removing the birdguard mesh.
Brewer's Windmaster is designed for solid-fuel systems, holding a steady draught whatever the wind direction or strength. It's made in stainless steel with a terracotta finish and fixes with a sleeve, external legs and straps. Sizes range from the Brewer Windmaster Cowl - Solid Fuel 125mm through 150mm and 178mm to the Brewer Windmaster Cowl - Solid Fuel 200mm. The Econocowl® Anti-Downdraught Cowl is another option for coal, wood, oil and smokeless fuels, with a 25mm square mesh, for 150 to 250mm pots.
A chimney that's no longer in use still needs a little airflow to stay dry, but it shouldn't admit rain or birds. The Brewer Capper Cowl - Strap Fixing sits on 150 to 250mm pots with a small air gap underneath, and Brewer states it's for unused chimneys only. The Colt Top Lid 3 Cowl - Strap Fix does the same job on 125 to 250mm pots, and the Econolid® Chimney Cap - Strap Fixing suits 150 to 250mm pots.
At the bottom of a relined chimney, a flex adaptor joins the stove pipe to the flexible liner. Both are stainless steel, with thumbscrews or wingnuts to clamp the liner and optional holes for self-tapping screws. Choose the Chimney Liner Flex Adaptor - 125mm or 150mm to match the liner, or the Chimney Liner Increasing Flex Adaptor - 125 x 150mm to step up from a 125mm stove outlet to a 150mm liner. Colt versions are also available, such as the Colt Chimney Liner Flex Adaptor MA - 150mm.
A pot hanger supports a 125mm flue liner from the top of the chimney pot. The Brewer Sleeve Pot Hanger - 125mm features a circular plate with a sleeve that fits into the liner, secured by stainless-steel straps. The Brewer Clamp Pot Hanger - 125mm uses a circular rain flange screwed to the liner, with external pot legs and a strap.
Rain, hail or birds drumming on a metal terminal can be heard inside. Brewer's Peacemaker Mat is a 300mm self-adhesive composite mat that adheres to the top of the terminal to deaden the noise, and it's designed not to degrade in sunlight or UV.
Start with what’s going wrong. If birds are nesting in a working flue, fit a birdguard with the appropriate mesh for the fuel. If smoke blows back into the room on windy days, an anti-downdraught cowl such as a Colt Rotorvent or a MAD spinner will help the flue keep drawing, and Brewer’s Windmaster does a similar job on open fires and stoves. All-purpose cowls and birdguards with a rain cap keep rain off the fire. A chimney that’s no longer used only needs a capper, top lid or chimney cap. If the noise of rain or birds on the terminal is the problem, a Peacemaker Mat will quieten it.
The fuel determines the mesh. Gas fire flues require the finer mesh of a model made to BS 5871, and the U.F.O. Mk II covers all gas appliances to BS 5871 parts 1, 2 and 3. Solid fuel produces soot and tar that can block a fine mesh, so wood and coal need a larger mesh or no mesh at all, which is why Colt recommends removing the birdguard on its all-purpose cowls for coal and wood. Revolving cowls like the Rotorvent shouldn't be used where wet or unseasoned wood is burned.
Strap-fixed cowls are sized by the pot's internal diameter, usually 150 to 250 mm or 170 to 250 mm, and many Colt models also specify a maximum outside diameter of 285 mm. Balloon birdguards are sized to the pot opening. Liner-mounted cowls and adaptors are sized to the liner, typically 125 mm or 150 mm. For square pots, use a square birdguard rather than a round one.
Cowls are fitted at height, so use proper access equipment. On a chimney serving a gas appliance, the cowl should be fitted by a Gas Safe registered engineer, who will check that the flue performs correctly afterwards. For wood or coal, a HETAS registered installer or a chimney sweep can confirm that the cowl suits the appliance, ideally after the flue has been swept. A chimney cowl isn't a replacement for a boiler flue terminal: only accessories approved by the boiler manufacturer should be fitted to a room-sealed boiler flue.
If you are relining a chimney, our flexible flue liner range covers Schiedel Triplelock and Tecnoflex liners, along with their terminals and clamps. For boiler flues, see our flue terminal guards, and for air bricks and vents, see our ventilation cowls. More Brewer cowls are on our Brewer brand page, and you'll find flashing, gas vent and twin wall systems in our full flue supplies range.
We've been supplying heating engineers and installers for more than 50 years. Free UK delivery applies to qualifying orders, and our team on 0800 801090 can help you match a cowl to the chimney and fuel.
What does a chimney cowl do?
A chimney cowl sits on top of the pot or liner to stop rain, birds and debris getting into the flue, and some types also reduce downdraught by using the wind to help the flue draw. On a disused chimney, a capper or top lid seals the top while allowing a small amount of ventilation.
Do I need a cowl on my chimney?
Not always, but most chimneys benefit from one. A working flue usually needs at least a birdguard to stop nests blocking it, and a chimney with downdraught problems may need an anti-downdraught cowl. An unused chimney should be capped to keep rain and birds out.
Which cowl is best for downdraught?
Wind-driven revolving cowls, such as the Colt Rotorvent range and MAD spinner cowls, are the usual choice for persistent downdraught. Static anti-downdraught cowls, like the Brewer U.F.O. Mk II, also work well, particularly on gas fires. Downdraught can also arise from a chimney that's too short or from nearby buildings, so it's worth having the cause checked.
What's the best cowl for a wood burner?
Use a cowl designed for solid fuel, such as the Brewer Windmaster, or one with a larger mesh, like the 25mm square mesh on the Econocowl®. Fine gas-flue mesh can become clogged with soot and tar. Revolving cowls shouldn't be used when burning wet or unseasoned wood, and the cowl should meet the stove manufacturer's flue requirements.
Can I use any birdguard on a gas fire flue?
No. Gas fire flues require a birdguard made for gas, with the finer mesh specified by BS 5871, such as the High Top Birdguard - Gas Flue Only or the Brewer gas/oil birdguards. Work on a chimney serving a gas appliance should be carried out by a Gas Safe registered engineer.
How do I cap a disused chimney?
Fit a capper or top lid, such as the Brewer Capper Cowl or the Colt Top Lid 3, which keep out rain and birds while leaving a small gap for ventilation. Fit only one to a chimney that's no longer connected to any appliance, and ensure the room below still has some ventilation into the flue to help it stay dry.
What size chimney cowl do I need?
Measure the internal diameter of the chimney pot. Most strap-fixed cowls fit pots with internal diameters of 150 to 250 mm or 170 to 250 mm, and Colt lists a maximum outside diameter of 285 mm. Liner-mounted cowls and adaptors are sized to the liner, usually 125 mm or 150 mm, and square pots need a square birdguard.
Can I fit a cowl to a boiler flue?
Not a chimney cowl. A modern room-sealed boiler flue terminal should be fitted only with accessories approved by the boiler manufacturer. If the terminal is less than 2 m above ground level, or above a balcony, flat roof or walkway, it needs a flue terminal guard instead.